The centerline of the water closet is 18 inches 455 mm from the side wall.
Ada bathroom stall door size.
An example of a single ada bathroom layout.
All entrances and exterior and interior exit doors regardless of the occupant load shall be made accessible to persons with disabilities.
Doors cannot swing into required clear floor or ground spaces in these specific instances.
If you are ordering and installing commercial restroom stalls you ll need the right bathroom partition dimensions.
5 common ada restroom compliance mistakes.
Multiple toilet stall layouts.
The ada compliant restroom.
Use our guide to get your order perfect.
Standard bathroom stall sizes rarely vary and tend to be 36 inches wide and 60 inches deep.
Clear floor space at controls for automatic and power assisted doors and gates 404 3 5 fixture clearances in toilet and bathing facilities except those that are single user where wheelchair space beyond the door swing is provided 603 2 3.
The minimum width of the stall is 60 inches 1525 mm.
Generally stall doors open inward but for ada accessible stalls the doors should open outward to make it easier for those with accessibility.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
The overall width should equal the sum of adding up each stall width.
Over size panels and door for extra privacy are also available.
However stall depth can be anywhere between 48 inches to 78 inches as needed.
Size min 3 0 wide 32 clear when 90 open and 6 8 in height.
Certain ada compliance issues seem to crop up more frequently than others but it s important to note that the following is not an exhaustive list.
The standards specify the location of toilet rooms in two instances.
Figure 30 a standard stall.
Door hardware operable with a single effort without requiring ability to grasp hardware.
Where toilet rooms are provided in multi story facilities that are exempt from the requirement for vertical access between stories 206 2 3 ex.
1 or 2 a toilet room must be provided on a story that is connected to an accessible entrance by an accessible route 213 1.
To see all of the ada compliance requirements see the 2010 ada standards for accessible design at www ada gov.
Figure 30 a standard stall.
The factory will determine pilaster sizes from the stall width and door width sizes that we give them see chart click on picture and then expand.
Maximum height for a door is 71 1 2 and.