I would be inclined to provide an accessible dressing room in each dressing room area.
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308.
Doors shall not swing into the room unless a clear floor or ground space complying with 305 3 is provided beyond the arc of the door swing.
According to ansi 803 4 and ada 4 35 4 a bench is required in all accessible fitting rooms.
Ada standards for accessible design can be downloaded from www ada.
The standards specify the location of toilet rooms in two instances.
803 5 coat hooks and shelves.
For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
If they are in a cluster 5 percent or at least one must be accessible.
The required number of accessible dressing rooms.
The americans with disabilities act of 1990 ada established a series of accessible design requirements for the construction of hotels and other lodging facilities that apply to the design of ada hotel rooms most of these regulations remain today while a few were updated in 2010 to promote greater accessibility.
If you want a more specific response you can contact the ada information line at 800 514 0301 and the division of state architect at 916 445 8100.
I don t think i ve ever seen anything re.
A bench complying with 903 shall be provided within the room.
Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383.
When provided dressing fitting or locker rooms must be accessible and comply with all adaag provisions.
There must be an accessible route through the door and to all elements required to be accessible in the room.
When designing an accessible fitting room remember to provide the required clear floor space along with a code compliant bench.
Where toilet rooms are provided in multi story facilities that are exempt from the requirement for vertical access between stories 206 2 3 ex.
Or for answers to.
Benches must be 42 inches long between 20 and 24 inches deep and 17 to 19 inches high.
1 or 2 a toilet room must be provided on a story that is connected to an accessible entrance by an accessible route 213 1.