The bar must be 1 1 4 to 1 1 2 inches in diameter.
Ada toilet grab bars requirements.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
The ada standards do not require this grab bar but allow a second grab bar to be within the 12 clearance above the horizontal grab bar 609 3 if there is a separation of 1 min.
In an accessible bathroom grab bars are critical whether they are in a shower stall or around a toilet.
Grab bars in toilet stall requirements.
A summary of these requirements is below.
Toilets need to have horizontal bars behind and next to them and a vertical bar in front.
An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
Grab bar code requirements are included in the standard ansii icc a117 1 of the international code council.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum from the rear wall and extending 54 inches 1370 mm minimum from the rear wall.
Toilet paper dispensers 604 7 toilet paper dispensers must be within accessible reach from the water closet.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum.