Doorways shall have a minimum clear opening of 32 in 815 mm with the door open 90 degrees measured between the face of the door and the opposite stop.
Ada toilet stall door width.
The minimum width of the stall is 60 inches 1525 mm.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
Standard toilet stalls are 36 wide by 60 depth.
Toilet partitions and the americans with disabilities act ada restroom partitions are classified as either a standard stall or an alternative stall.
A visual representation of these two can be found easily by reviewing figure 30 a for standard stalls and figure 30 b for alternative stalls.
Figure 30 a standard stall.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
These common pitfalls can spell trouble for ada compliance not just in restrooms but in the rest of your facility.
In this stall the centerline of the toilet must be exactly 18 inches from the side of the toilet to the wall and with clear space more than 32 inches to the wall.
Figure 30 a standard stall.
Door closers often require more than 5 pounds of force to open and the last thing you need if you re in a hurry to get there is to be hindered by a door that s too heavy to open ada compliance misconceptions.
1 or 2 a toilet room must be provided on a story that is connected to an accessible entrance by an accessible route 213 1.
Clear width is 32 inches 815 mm minimum measured from the face of the door open 90 degrees to the face of the doorstop.
Partition stalls can have a minimum depth of 48 in most cases or up to 78 depth if needed.
Multiple toilet stall layouts.
The centerline of the water closet is 18 inches 455 mm from the side wall.
If there are at least 6 stalls at least one must be further outfitted with parallel grab bars on each side and an outward swinging self closing door.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
An example of a single ada bathroom layout.
The standards specify the location of toilet rooms in two instances.
Where toilet rooms are provided in multi story facilities that are exempt from the requirement for vertical access between stories 206 2 3 ex.